TEL: 0750-3670689

0750-3670386

NEWS:

LP series - the external type

  • LP series - the external type
  • Product Feature

      LP series aluminum alloy guide rail type magnetostrictive displacement sensor, which is suitable for the need to external installation of linear displacement measuring occasions, with strong anti-interference ability, allowable WenYu wide, non-contact measurement will never wear, high resolution, high precision, easy to replace, the advantages of online intelligent diagnosis.
         Suspension magnet installed directly on the moving parts, measured with the sensor does not contact, maximum permissible lateral offset can be up to + / - 2 mm, widely used in all kinds of CNC machine tools, such as stamping machines, building materials machinery, woodworking machinery, etc.

     

    Technical Parameters

     

      Analog Output SSI Output
    Project Name Standard/Parameter Standard/Parameter
    Measurement Range 25-3500mm 25-3500mm
    Output Signal 0~20mA,4~20mA; 0~10V,-10~+10V 24,25,26bit binary system or  Gray code
    Resolution 16 bit D/A  0.5/1/ 2/ 5/ 10/ 20/ 50/ 100um
    Non-linearity <±0.01%F.S.(min±50μm) <±0.01%F.S.(min±40μm)
    Repeatability <±0.001%F.S.(min±1μm) <±0.001%F.S.(min±1 readings)
    Response Frequency Related to the range Related to the range
    Operating Voltage 24VDC (-15/+20%)
    Working Temp - 40℃~+85℃
    Protective Ability IP67
    Way To Install Tingle,match M5X20Full dog point socket set use

     

    Boundary Dimension

     

     C magnet

     

     M magnet

     

    Boundary Dimension

     

    Analog Output Needle Size Line Color Definition SSI Output Needle Size Line Color Definition
    1 grey Output Signal:0-20mA,0-10V 1 grey (-)data
    2 pink Signal earth 2 pink (+) data
    3 yellow (+)communication interface 3 yellow (+) clock
    4 green (-)communication interface 4 green (-) clock
    5 palm +24VDC(±10%) 5 palm +24VDC(±10%)
    6 white A direct current source 6 white A direct current source
          7   throw out of gear

     

    Analog Output Needle Size Line Color Definition Modbus Output Needle Size Line Color Definition
    1 grey Output Signal:4-20mA,0-10V 1 grey A(RS485)
    2 pink Signal earth 2 pink B(RS485)
    3 palm +24VDC(±10%) 3 palm +24VDC(±10%)
    4 white A direct current source 4 white A direct current source

     

    状态指示:

     

    Analog Output Indicator State Definition
    Green light Regular work
    Green light flashing Programme state
    Red light flashing The circular leave effective range
    Red light Detect the circular or damage

     

    SSI Output Indicator State Definition
    Green light Regular work
    Green light flashing Programme state
    Red light flashing The circular leave effective range
    Red light Detect the circular or damage

     

Hits:  UpdateTime:2015-01-19 17:28:17
Previous:No Information  Next:LP series - the external type