LF series - flexible rod

2015-01-19 783

Product Feature:

  LF series flexible rod type magnetostrictive displacement sensor, suitable for measuring the large travel and replace the cramped use occasion.Products using the flexible rod can realize linear displacement measurement, can also realize the curve of displacement measurement, compared with the rigid rod products, LF series products reduced the replacement installation required space, also reduced the difficulty of transportation.

  Strong anti-jamming capability, allowable WenYu wide, never wear.Optional output signals include: analog, SSI (synchronous serial interface), etc.

 

  Analog Output SSI Output
Project Name Standard/Parameter Standard/Parameter
Measurement Range 500-10000mm 500-10000mm
Output Signal 0~20mA,4~20mA; 0~10V,-10V~+10V  24,25,26 bit binary system or Gray code
Resolution 16 bit D/A  2/ 5/ 10/ 20/ 50/100um
Non-linearity <±0.02%F.S.(min±100μm) <±0.02%F.S.(min±80μm) 
Repeatability <±0.001%F.S.(min±1μm) <±0.001%F.S.(min±1 readings)
Response Frequency Related to the range Related to the range
Operating Voltage 24VDC (-15/+20%)
Working Temp - 40℃~+85℃
Protective Ability

Without IP30 when protecting tube, after loading, electronic parts:IP67,

Rod pressure:35MPa continuous/70MPa peak

Way To Install Sensors for two M4X59 screws, between ontology and rod rod built-in installation, M18X1. 5 screw

 

Boundary Dimension:

 

Sensor ontology

 

Pipe covering

 

The circular is commonly used
OD33 magnet ring OD25.4 magnet ring OD17.4 magnet ring
thickness of the 8mm thickness of the 8mm thickness of the 8mm

 

Analog Output Needle Size Line Color Definition SSI Output Needle Size Line Color Definition
1 grey Output Signal:0-20mA,0-10V 1 grey (-)data
2 pink Signal earth 2 pink (+) data
3 yellow (+)communication interface 3 yellow (+) clock
4 green (-)communication interface 4 green (-) clock
5 palm +24VDC(±10%) 5 palm +24VDC(±10%)
6 white communication interface 6 white communication interface
      7   不接

 

Analog Output Needle Size Line Color Definition Modbus Output Needle Size Line Color Definition
1 grey Output Signal:4-20mA,0-10V 1 grey A(RS485)
2 pink Signal earth 2 pink B(RS485)
3 palm +24VDC(±10%) 3 palm +24VDC(±10%)
4 white communication interface 4 white communication interface

 

Analog Output Indicator state Definition
Green light Regular work
Green light flashing Programme state
Red light flashing The circular leave effective range
Red light Detect the circular or damage

 

SSI Output Indicator state Definition
Green light Regular work
Green light flashing Programme state
Red light flashing The circular leave effective range
Red light Detect the circular or damage